Solarlite Euro Bronze
Solarlite Euro Bronze: Performance Data For Monolithic Glass
Glass Configuration | UV | Visible Light | Solar Energy | ||||||||
Solarlite Euro Bronze | % | % | % | % | % | ||||||
(MM) | Transmittance | Transmittance | Reflectance Outdoors | Reflectance Indoors | Transmittance | Reflectance | Absorption | Solar Factor EN410 | SHGC | SC | U Value W/M2K |
4 | 9 | 24 | 16 | 36 | 34 | 14 | 52 | 0.49 | 0.50 | 0.57 | 5.8 |
5 | 7 | 22 | 14 | 36 | 30 | 12 | 58 | 0.47 | 0.48 | 0.55 | 5.7 |
6 | 6 | 20 | 13 | 36 | 27 | 11 | 62 | 0.46 | 0.45 | 0.53 | 5.7 |
8 | 4 | 16 | 10 | 36 | 22 | 9 | 69 | 0.44 | 0.44 | 0.51 | 5.7 |
10 | 3 | 14 | 8 | 36 | 18 | 7 | 75 | 0.41 | 0.42 | 0.48 | 5.6 |
– Performance data is based on representative samples of factory production. Actual values may vary slightly due to variations in the production process.
– Tabulated data is based on NRFC methodology using the LBL Windows 5.2 Software and where noted European methodology using WinDat WIS version 3.0.1 software.
– SF = Solar Factor (EN410) also known as g-value.
Solarlite Euro Bronze : Performance Data for IG Unit (6mm/16mm air space/6mm
Visible light Transmission VLT | Visible light Reflectance | SC | Solar Factor(g) EN 410 | U-Value Imperial | U-Value EN 673 W/m²*K | |||
Ext. | Int. | Winter | Summer | |||||
Trulite Clear | 19% | 14% | 37% | 0.38 | 0.33 | 2.80 | 2.70 | 2.70 |
SG 500 -Hard coat Low E#3 | 18% | 14% | 35% | 0.32 | 0.28 | 1.90 | 1.80 | 1.80 |
Single Silver Low E#3 | 15% | 14% | 32% | 0.31 | 0.27 | 1.80 | 1.60 | 1.60 |